Thiết kế máy hấp tiệt trùng nhanh dùng cho các dụng cụ y tế
Tóm tắt: 487
|
PDF: 438
##plugins.themes.academic_pro.article.main##
Author
-
Le Hoai NamThe University of Danang - University of Science and Technology, Danang, VietnamDang Phuoc VinhThe University of Danang - University of Science and Technology, Danang, VietnamTran Thai DuongThe University of Danang - University of Science and Technology, Danang, VietnamPham Xuan DatThe University of Danang - University of Science and Technology, Danang, VietnamNguyen Le Hoai AnThe University of Danang - University of Science and Technology, Danang, VietnamTran Van TienThe University of Danang - University of Science and Technology, Danang, VietnamNguyen Tan MinhThe University of Danang - University of Science and Technology, Danang, Vietnam
Từ khóa:
Tóm tắt
Để đảm bảo an toàn cho bệnh nhân thì việc tiệt trùng các thiết bị y tế được yêu cầu cao. Tuy nhiên, máy hấp truyền thống không phù hợp cho một số trường hợp do kích thước lớn, cồng kềnh và tốn thời gian. Để giải quyết vấn đề này, nhóm đã phát triển máy hấp tiệt trùng nhanh - một giải pháp nhỏ gọn và dễ di chuyển. Bài báo này trình bày quy trình thiết kế và chế tạo a máy hấp tiệt trùng nhanh cho thiết bị y tế. Máy có kích thước nhỏ, cấu trúc nhẹ và dễ sử dụng. Máy có thể hoàn thành một chu trình tiệt trùng thiết bị trong khoảng 3,5 phút. Vỏ máy được làm bằng thép không gỉ, chắc chắn với một bảng điều khiển số giúp việc quản lý được thuận tiện. Máy đã được thử nghiệm và xác nhận tuân thủ các tiêu chuẩn cần thiết để đảm bảo hiệu quả khử trùng. Kết quả nghiên cứu nhấn mạnh tính hiệu quả và an toàn của máy trong việc tiệt trùng các thiết bị y tế.
Tài liệu tham khảo
-
[1] Gupta, "Sterilization 101: How Does a Laboratory Autoclave Work?”, Consolidated Sterilizer Systems, 2023. [Online]. Available: https://consteril.com/how-does-a-laboratory-autoclave-work/ [Accessed: September 19, 2023].
[2] S. Petrofsky et al., “The effect of the moisture content of a local heat source on the blood flow response of the skin”, Arch Dermatol Res, vol. 301, no. 8, pp. 581-585, 2009.
[3] Panta, A.K. Richardson, and I.C. Shaw, “Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities”, J Infect Dev Ctries. vol. 13, no. 10, pp. 858-864, 2019.
[4] A. Coulter, C.A. Chew-Graham, S.W. Cheung, and F.J.T. Burke, “Autoclave performance and operator knowledge of autoclave use in primary care: A survey of UK practices”, Journal of Hospital Infection, vol. 48, no. 3, pp. 180-185, 2001.
[5] P. Davila, L.G. Rodríguez, S. Chiussi, J. Serra, and P. González, “How to Sterilize Polylactic Acid Based Medical Devices?”, Polymers, vol. 13, no. 13, 2021.
[6] Crow, “Sterilization processes. Meeting the demands of today´s health care technology”, Nurs. Clin. N. Am, vol. 28, pp. 687–695, 1993.
[7] Q. Qiu, W.Q. Sun, and J. Connor, “Sterilization of Biomaterials of Synthetic and Biological Origin”, Comprehensive Biomaterials II, vol. 4, pp. 180-199, 2017.
[8] TL Plus Engineering, “The temperature and pressure chart of saturated steam”, TL Plus Engineering Company Limited, 2023. [Online]. Available: https://tlplus-engineering.com/bang-nhiet-do-ap-suat-va-nang-luong-cua-hoi-bao-hoa [Accessed: September 19, 2023].
[9] Statimusa, “Statim 2000 & 5000 Field Training Manual”, Statim, 2023. [Online]. Available: https://statimusa.com/wp-content/uploads/2017/10/Statim-2000-5000-Field-Training-Manual.pdf. [Accessed: September 19, 2023]
[10] Legatek, “The set of surgical instruments for vitrectomy”, Legatek, 2023. [Online]. Available: https://legatek.com.vn/san-pham/bo-dung-cu-phau-thuat-thuy-tinh-the/. [Accessed: September 19, 2023].
[11] K. Nguyen, Q.D. Nguyen, and P.V. Dang, “Design and Manufacturing a Smart Suitcase Using Image Processing”, The University of Danang - Journal of Science and Technology, vol. 20, no. 8, pp. 93-98, 2022.
[12] T. Vo, P.V. Dang, T.N. Ngo, H.-N. Le, and L.H.T. Do, “Restaurant Serving Robot with Double Line Sensors Following Approach”, in Proc. of the 2019 IEEE International Conference on Mechatronics and Automation (ICMA), Tianjin, China, 2019, pp. 235-239.
[13] T. Vo, P.V. Dang, H.-N. Le, T.N. Ngo, and L.A. Doan, “Reinforcement Q-learning PID Controller for a Restaurant Mobile Robot with Double Line-Sensors”, in Proc. of the 4th International Conference on Machine Learning and Soft Computing (ICMLSC '20), pp.164–167, 2020.
[14] -N. Le, P.V. Dang, A.-D. Pham, and N.T. Vo, “System identifications of a 2DOF pendulum controlled by QUBE-servo and its unwanted oscillation factors”, Archive of Mechanical Engineering, vol. 67, pp. 435-450, 2020.
[15] P.V. Dang, N.T. Vo, H.-N. Le, A.-D. Pham, T.N. Ngo, and L.A. Doan, “On the Impact Test Methodology for the Quick Estimation of Natural Frequency of the Mechanical Systems”, Lecture Notes in Mechanical Engineering, Springer, Singapore, 2021, pp. 191-201.

